Product DetailsThe SCB18-125kVA Dry Transformer is a high-performance, safe, and energy-efficient power distribution solution. Designed without the need for transformer oil, it is perfect for indoor environments and areas where environmental concerns are a priority, offering an ideal balance of safety, reliability, and low-maintenance operation.Key FeaturesSafe and Flame Retardant: The SCB18-125kVA transformer is built to be pollution-free and explosion-proof, ensuring the highest safety standards.
Hubungi sekarang
Product DetailsThe SCB12-125kVA Dry Transformer is a reliable, safe, and efficient power distribution solution, designed without the use of transformer oil. This makes it an ideal choice for indoor installations and environmentally sensitive applications, providing optimal safety and energy efficiency while reducing environmental impact.Key FeaturesSafe and Flame Retardant: This transformer is designed to be pollution-free, explosion-proof, and equipped with a high flame-retardant rating.
Hubungi sekarang
Features:- Utilizes high-quality insulating oil or dry design, offering excellent insulation performance and heat dissipation effects; equipped with explosion-proof devices to ensure operational safety.- Low noise: Optimized core and winding structures effectively reduce the noise level during operation, making it particularly suitable for noise-sensitive environments.- Strong resistance to short circuits: Amorphous alloy materials have high mechanical strength, capable of withstanding large short-circuit current shocks.- Small size, light weight: Compared to traditional silicon steel core tra
Hubungi sekarang
The S20-125 is an oil-immersed transformer with a rated capacity of 125kVA, offering high efficiency and energy savings for power distribution. As part of the S20 series, this model represents the new generation of transformers designed for optimal performance, reliability, and energy efficiency, ensuring compliance with the latest energy standards.Main FeaturesHigh Efficiency and Energy Saving: The S20-125 integrates advanced materials and an optimized design, achieving the latest energy efficiency standards.
Hubungi sekarang
The SCB14-125 is a three-phase dry-type power transformer designed with an encapsulated structure, cast in high-quality epoxy resin. It features foil winding technology on the high-voltage side, ensuring optimal performance and efficiency.
Hubungi sekarang
Technical ParametersRated capacity: 2500kVAVoltage level: 10kV/0.4kV or other configurationsCooling method: Oil-immersed self-cooling or dry air self-coolingConnection group: Yyn0 or Dyn11Insulation level: Class B or higherProtection level: IP20 or higherNo-load and load losses: Both are kept at a low level; specific values can be referenced in the technical specifications provided by the manufacturer.Application ScenariosThe SBH21-M.RL-2500 amorphous alloy transformer is suitable for various fields, including but not limited to:Industrial sector: Suitable for various factories, production wor
Hubungi sekarang
Rated capacity: 1000 kVAVoltage level: Customizable according to actual needs, common options include 10/0.4 kV, etc.Frequency: 50 Hz or 60 HzConnection group: Yyn0, Dyn11, etc.No-load loss: Relatively low, specific values need to be checked in the product manual.Load loss: Also relatively low, specific values need to be checked in the product manual.Insulation class: F or higherCooling method: Natural air cooling (AN) or forced air cooling (AF)Noise level: LowDimensions and weight: Depending on specific designApplications:Distribution link in power systems: Suitable for urban power grid trans
Hubungi sekarang
Technical ParametersKey Indicators:Rated Capacity: 1000 kVA (kilovolt-amperes), indicating the maximum apparent power that the transformer can transmit.Voltage Level: Specific voltage values for both the high-voltage and low-voltage sides are usually provided, such as 10/0.4 kV, etc.Short Circuit Impedance: An important parameter affecting system stability and the magnitude of fault currents.No-Load Loss: The electrical energy consumed by the transformer when there is no load, where amorphous alloy transformers perform exceptionally well.Load Loss: The energy loss when the transformer is opera
Hubungi sekarang
Product DetailsThe Pad-Mounted Transformer is a durable and efficient solution designed for safe and reliable power distribution in various commercial and industrial settings.
Hubungi sekarang
Main Features:(1) High Efficiency and Energy SavingLow loss design: Amorphous alloy materials have extremely low hysteresis loss and eddy current loss, significantly reducing no-load and load losses, and improving the energy efficiency ratio.Energy-saving effect: Compared with traditional silicon steel sheet transformers, the energy efficiency ratio is significantly improved, and long-term operation can greatly save electricity.(2) Environmental Protection and SafetyInsulation and heat dissipation: High-quality insulating oil or dry design is adopted, with good insulation performance and heat
Hubungi sekarang
Technical ParametersThe technical parameters include but are not limited to:Rated capacity: 630 kVAVoltage levels: Depending on the specific application, various combinations are possible, such as 10/0.4 kV, etc.Frequency: 50 Hz or 60 HzCooling method: Typically oil-immersed self-cooling or forced air-coolingInsulation level: According to national standardsNoise level: Relatively low, as amorphous alloy materials help reduce noiseNo-load loss: Much lower than traditional silicon steel sheet transformersLoad loss: Also superior to traditional transformersApplicationsThe SBH21-M.RL-630 amorphous
Hubungi sekarang
Technical ParametersRated Capacity: 1250 kVA (kilovolt-amperes), indicating the maximum apparent power that the transformer can transmit.Voltage Level: Specific primary and secondary voltages should be referenced in the product specification sheet, but typically, this type of transformer is suitable for medium and low voltage power grids, such as configurations like 10 kV/0.4 kV.Frequency: 50 Hz or 60 Hz, depending on the standard of the power system in the region where it is used.Connection Group: Common types include Dyn11, Yyn0, etc., which specify the electrical connection method between t
Hubungi sekarang
Technical ParametersCapacity: 1600 kVA (kilovolt-amperes), indicating the transformer's maximum output power.Voltage Levels: Specific values are not provided, but typically include two voltage values for the high-voltage and low-voltage sides.
Hubungi sekarang
Technical ParametersRated Capacity: 1250 kVA (kilovolt-amperes), indicating the maximum apparent power that the transformer can handle.Voltage Level: Specific values are not given, but it typically indicates the operating voltage range of the primary side (input) and secondary side (output).
Hubungi sekarang
Technical ParametersCapacity: 2000 kVA (kilovolt-amperes), indicating its maximum output power.Voltage Level: Specific values should be referenced from the product manual or information provided by the manufacturer, but typically indicate the rated voltage for both the primary and secondary sides.Frequency: Generally 50 Hz or 60 Hz, suitable for different regional grid standards.Insulation Class: Choose appropriate insulation materials based on the actual application environment to ensure electrical safety.Cooling Method: Natural air cooling or forced air cooling, among others.Noise Level: Low
Hubungi sekarang
Technical Parameters:Rated Capacity: 800 kVA (This refers to the maximum power that the transformer can continuously transmit.)Voltage Level: Specific values for the primary (input side) and secondary (output side) voltages, such as 10/0.4 kV, depending on the actual application needs.Frequency: Usually 50 Hz or 60 Hz, suitable for different national and regional grid standards.No-load Loss: Represents the amount of energy consumed by the transformer when there is no load.Load Loss: The energy consumed by the transformer when operating at full load.Short-circuit Impedance: Reflects the degree
Hubungi sekarang
Technical ParametersFeatures:Rated capacity: 200 kVAVoltage level: Customizable according to application needs, for example, 10/0.4 kV, etc.Frequency: 50 Hz or 60 HzConnection group: Typically Dyn11 or other typesShort-circuit impedance: About 4% approximatelyNo-load loss: Considerably reduced compared to traditional silicon steel sheet transformersLoad loss: LowNoise level: Below standard valuesTemperature rise limit: Compliant with relevant national standards requirementsApplicationsThe SBH21-M.RL-200 amorphous alloy transformer is widely used in the following fields:Urban power grid renovat
Hubungi sekarang
Main FeaturesEnergy-Efficient and Cost-Effective: Utilizing amorphous alloy materials, this transformer reduces no-load and load losses, improving overall energy efficiency and reducing operational costs.Safe and Dependable: Built with high-quality insulation materials and equipped with explosion-proof devices, ensuring safe and secure operation.Quiet Operation: The optimized core and winding structure significantly lowers noise during operation, creating a quieter environment.High Short-Circuit Resistance: Amorphous alloy materials provide superior mechanical strength, allowing the transforme
Hubungi sekarang
Product DetailsThe inverter is designed to stabilize voltage and frequency fluctuations during operation, ensuring consistent performance. It includes built-in protection mechanisms such as overload, short circuit, and over-temperature protection to safeguard against abnormal conditions. Additionally, the inverter features intelligent monitoring to continuously assess the health of the system, transmitting real-time operational data for maintenance and troubleshooting.
Hubungi sekarang
Product DetailsThis metal-clad vacuum switchgear with VCP-W breakers is designed for high performance and safety. Built to comply with ANSI, NEMA, and IEEE standards, it features arc-resistant models to ensure protection during fault conditions. Its modular design allows for flexible configurations, accommodating a variety of breaker arrangements and auxiliary compartments.
Hubungi sekarang
Product DetailsThe GGD switchboard is a type of high voltage switchgear designed to distribute high-voltage energy to low-voltage devices efficiently. It plays a crucial role in power distribution systems, enabling the safe allocation and conversion of power according to circuit requirements. With its modular structure, high breaking capacity, and robust design, the GGD switchboard ensures reliable operation, exceptional stability, and adaptability to various environmental conditions.
Hubungi sekarang
Main FeaturesEnergy-saving and efficient: The use of amorphous alloy materials significantly reduces no-load and load losses, improving the energy efficiency ratio.Safe and reliable: High-quality insulating materials are used, equipped with explosion-proof devices to ensure safe operation.Low noise operation: The core and winding structure are optimized to effectively reduce the noise level during operation.Strong resistance to short circuits: Amorphous alloy materials have high mechanical strength and can withstand large short-circuit current shocks.Compact and lightweight: Small in size and
Hubungi sekarang
Main Features:Energy-efficient and efficient: The use of amorphous alloy materials significantly reduces no-load and load losses, improving the energy efficiency ratio.Safe and reliable: High-quality insulating materials are used, equipped with explosion-proof devices to ensure safe operation.Low noise operation: The core and winding structures are optimized to effectively reduce noise levels during operation.Strong resistance to short circuits: Amorphous alloy materials have high mechanical strength and can withstand large short-circuit current shocks.Compact and lightweight: Small in size an
Hubungi sekarang
Product DetailsThe Pole-mounted Transformer is a compact and cost-effective solution designed for pole-mounted installations, particularly in areas with limited infrastructure.
Hubungi sekarang